Description Technical data Schematic Programming Order overveiw Downloads |
||
Annunciator system LSC |
Type | BM Basic Module | RM Relay Module | PM Panel Module |
---|---|---|---|
View | |||
Part number | 832.600.012 | 832.600.022 | 832.600.000 |
Housing | 87.5 x 90 x 58mm DIN | 87.5 x 90 x 58mm DIN | 96 x 96 x 51 mm Front panel assembly |
Cutout | -- | -- | 92 x 92mm |
Installaton position | any | any | any |
Connections | Cage clamp terminal blocks 2.5mm2 | Cage clamp terminal blocks 2.5mm2 | -- |
Temperature range | 0°C - +55°C | 0°C - +55°C | 0°C - +55°C |
Degree of protection | IP20 | IP20 | IP40 |
Supply voltage | 24VDC +/-20% | 24VDC +/-20% | 24VDC +/-20% |
Flash frequency | 1 HZ | 1 HZ | 1 HZ |
Relay switching capacity | max. 3A / 250VAC | max. 3A / 250VAC | -- |
Max. power consumption | 5W | 3W | 2W |
Trip delay | ca. 10ms | ca. 10ms | ca. 10ms |
Recovery time | ca. 1s | ca. 1s | ca. 1s |
Expansion capability | max. 8 BM | max. 8 RM | max. 8 PM |
Bus length | 1000m | 1000m | 3m |
IMAGE (static)
The common alarm relay is activated by the first alarm and becomes inactive again when no further alarm conditions exist.
ACK (static until LQ)
The common alarm relay is activated by the first arriving alarm and becomes inactive again after the lamp acknowledgement. On the arrival of further alarms the collective alarm relay becomes active until the next lamp acknowledgement.
DYNAMIC
For each alarm arriving the common alarm relay becomes active in the cycle of the blinking frequency, until the lamp acknowledgement. On the arrival of further alarms the collective relay actively blinks again until the next lamp acknowledgement.
BLINK (dynamic/static)
The same functioning as for the common alarm DYNAMIC, but the relay remains statically active after the lamp acknowledgement until no further alarm conditions exist.
IMAGE (static)
Image of the alarm linkage. The relay becomes statically active by the first alarm condition originating from the linkage. The relay output is reset when no more alarm conditions exist.
ACKHQ (static until HQ)
The relay is statically activated by the alarm linkage until the horn annunciator has been acknowledged.
ACKLQ (static until LQ)
The relay remains statically active due to the alarm linkage until the lamp acknowledgement has been activated.
BLINK (dynamic/static)
The relay remains set in blinking mode whilst alarm conditions are communicated via the linkage. After acknowledgement of the alarms the relay remains statically active until no more alarm conditions are communicated via the linkage.
Artikelnummer | Bezeichnung | Zusatz | Bestand*1 | Preis*2 | ||
---|---|---|---|---|---|---|
832.600.000 | LSC PM Panelmodul lokal, 24VDC | 3 | 360.00 CHF | |||
832.600.012 | LSC BM Basismodul, 24VDC | mit 8 Eingänge inklusive LED | 8 | 602.00 CHF | ||
832.600.022 | LSC RM Relaismodul, 24VDC | mit 8 Ausgänge inklusive LED | 7 | 501.00 CHF | ||
832.600.030 | BCCS6 Buskabel 68mm / 6-polig | 57 | 11.00 CHF | |||
832.600.031 | BCCS4 Buskabel 0.2m / 4-polig | 70 | 11.00 CHF | |||
832.600.032 | CIM Busanschlussmodul (LSC oder LSX) | 31 | 40.00 CHF | |||
832.600.033 | BCCL6 Buskabel 3.0m / 6-polig | 21 | 25.00 CHF | |||
832.600.090 | LSC PC Termi-Software inkl. Kabel 3.0m | 145.00 CHF | ||||
832.600.095 | LSC Programmierungskabel 3m | 3 | 48.00 CHF | |||
832.600.903 | Beschriftungseinschub LSC PM | Set à 3 Stk. | 919 | 9.00 CHF |
*1: Lagerbestände sind Richtwerte. Die Zuteilung erfolgt nach Bestelleingang. |
*2: Preise sind nicht verbindlich, Irrtum ist vorbehalten. |